Cathodic protection (CP) is a method of stopping steel from corroding by making it the cathode of an electrochemical cell. It is used on buried and submerged pipelines, storage tanks, well casings, jetties and reinforced concrete. Done properly, it can extend the life of a structure by decades.
This guide explains the basic idea, the two main types of system, how to tell if protection is working, and how to choose between them.
Why steel corrodes
Corrosion is an electrochemical reaction. For it to happen, four things are needed:
An anode, where metal dissolves (steel turns into iron ions and rust)
A cathode, where the electrical current returns to the metal
An electrolyte, such as moist soil or seawater, that carries ions
A metallic path connecting the anode and cathode, which is the steel itself
On a buried pipeline, small differences in the steel, soil moisture, oxygen and coatings create anode and cathode areas on the same surface. The anode areas lose metal. That is where pits and leaks start.
The basic idea of cathodic protection
CP removes the anode areas from the steel. A stronger source of electrons is supplied to the structure so the whole surface becomes a cathode. Current flows from an external anode, through the soil, onto the pipe. The pipe receives current instead of losing metal, and the external anode is the part that is consumed.
There are two ways to supply that current.
Sacrificial anode systems
A sacrificial (galvanic) system connects the steel to a more reactive metal, usually magnesium, zinc or aluminium. The difference in natural potential drives current without any power supply. The anode corrodes in place of the steel and has to be replaced when it is used up.
Advantages
No external power needed
Simple, low maintenance and few moving parts
Low risk of overprotection or interference with nearby structures
Limits
Small driving voltage, so output is limited
Works best in lower-resistivity soil and on well-coated structures
Anodes need periodic replacement
Typical uses: short pipelines, well-coated pipe, tanks, small structures, and local protection at specific points.
Impressed current systems
An impressed current system uses a rectifier that converts AC mains power to a controlled DC output. The positive terminal connects to a groundbed of inert anodes (such as mixed metal oxide, graphite or high-silicon cast iron). The negative terminal connects to the structure. Current flows from the groundbed through the soil to the structure.
Advantages
High and adjustable current output
Suitable for large or poorly coated structures and high-resistivity soil
Long anode life, with the output tuned as conditions change
Limits
Needs a power source and regular monitoring
Higher installation and operating cost
Wrong settings can cause overprotection or stray current effects on nearby structures
Typical uses: long pipelines, large tank farms, plant piping, and structures in high-resistivity soil.
Sacrificial anode vs impressed current at a glance
Sacrificial anode
Impressed current
Power source
None
Rectifier (AC to DC)
Current output
Low, fixed
High, adjustable
Best for
Small, well-coated structures
Large or long structures, poor coating
Maintenance
Low
Regular checks needed
Interference risk
Low
Higher, needs care
Upfront cost
Lower
Higher
How do you know it is working?
Protection is checked by measuring the structure-to-soil potential with a reference electrode (usually copper/copper sulphate) placed on the soil above the pipe, connected to a high-impedance voltmeter.
The commonly used criteria for steel are:
A polarised potential of -850 mV or more negative relative to a copper/copper sulphate electrode, or
At least 100 mV of polarisation shift
Potentials are normally read at test stations along the pipeline. Readings taken with the current on include a voltage drop error, so engineers use techniques such as instant-off measurements, coupons or close-interval surveys to get the true polarised potential.
The exact criteria and test methods depend on the standard you follow, for example AMPP (formerly NACE) SP0169 or ISO 15589-1 for pipelines. Always check the current edition for your project.