How to Read Cathodic Protection Potential Readings (and What They Tell You)

By Munawar Ahmad Mangla, Cathodic Protection Engineer

    What a Potential Reading Is

    A cathodic protection (CP) potential reading is a voltage measurement between the protected structure and a reference electrode placed in the electrolyte (soil or water).

    What You Need to Measure It

    • A high-impedance digital voltmeter
    • A reference electrode, most commonly copper/copper sulfate (CSE) for soil, or silver/silver chloride for seawater and some other environments
    • A test lead connected to the structure at a test station or other contact point
    • Good electrical contact between the electrode and moist soil

    Readings taken against different electrodes are not directly comparable without correction.

    The Common Protection Criteria

    AMPP (formerly NACE) standards for buried steel structures give criteria such as:

    • A polarized (instant-off) potential of -850 mV or more negative relative to CSE
    • A minimum of 100 mV of cathodic polarization from the native potential

    Details, limits and special cases differ between standards and structures, so follow the standard or specification that applies to your project. [Mention the standard or client specification you work to.]

    The Problem of IR Drop

    When CP current flows through the soil, it creates a voltage drop between the structure and the reference electrode. That voltage drop is called IR drop, and it is included in a reading taken while the current is on. The result is a reading that looks more negative than the structure’s true polarized potential, which can make an underprotected structure look fine.

    That is why people measure both:

    • On potential: measured with the CP current flowing
    • Instant-off potential: measured immediately after all current sources are briefly interrupted, which removes most of the IR drop

    Current interrupters installed in the rectifier or on galvanic anode connections let you read instant-off potential accurately. Reading too late after interruption lets the structure depolarize and gives a misleadingly low value.

    Step-by-Step: Taking a Basic Reading

    1. Place the reference electrode on the ground directly above or close to the structure, on moist soil
    2. Connect the voltmeter’s negative terminal to the reference electrode and the positive terminal to the structure
    3. Record the on potential
    4. If interrupters are available, record the instant-off potential
    5. Note the date, test location, electrode type, weather and soil moisture

    [Add a photo of a test station or measurement setup from your own work.]

    Interpreting Results

    Reading (instant-off, vs CSE)What it usually suggests
    More negative than -850 mVMeets the commonly used criterion, if measured correctly
    Between native potential and -850 mVCheck the 100 mV polarization criterion or investigate
    Close to native potentialLittle or no effective protection
    Very negative on a coated structurePossible overprotection, with a risk to coating and, on some steels, hydrogen damage

    Treat a single number with caution. Trends over time, seasonal moisture changes and nearby interference all matter.

    Common Mistakes

    • Not recording the reference electrode type
    • Relying on on-potential readings and ignoring IR drop
    • Poor electrode contact in dry or rocky soil
    • Ignoring stray current or interference from other systems
    • Taking readings once and never trending them

    Conclusion

    Potential readings are the everyday health check of a cathodic protection system. Measure carefully, remove IR drop where you can, compare against the right criteria, and watch the trend. [Add your call to action and contact details.]